Antminer S23 Hyd 3U 1160 TH/s – Hydro Bitcoin ASIC Miner
Payment methods
- Bank transfer
- Interac e-Transfer
- Cryptocurrency
An itemized invoice, a named recipient and confirmation after funds are received.
Payment details and next steps
1. Bank transfer
Pay in Canadian dollars to our Scotiabank business account. The beneficiary name shown on our void cheque is CAPITAINE MINAGE INC.
- Beneficiary
- CAPITAINE MINAGE INC.
- Bank
- Scotiabank
- Currency
- CAD
- Transit / branch
- 71191
- Institution
- 002
- Account number
- 0129615
Include your invoice number as the payment reference. Our void cheque is available on request.
International wire or another currency? Request the instructions for your bank before sending funds.
2. Interac e-Transfer
Send your Interac e-Transfer to the address below and include your invoice number in the message.
info@captainmining.com
Your financial institution’s limits apply. For a larger amount, contact us to arrange a bank transfer.
3. Cryptocurrency
For each order, we confirm the cryptocurrency, network, exact amount, receiving address and quote validity period.
Request my crypto payment instructionsYour payment in 3 steps
- Review your invoice: equipment, amount, currency and agreed terms.
- Make your payment using your invoice number as the reference.
- We verify receipt of funds and confirm the next steps for your order.
Pay after receiving your invoice and confirmation of availability. Delivery or installation follows the timeline agreed for your order.
Credit and debit cards are not accepted.
First order? Check the details with our team.

U3S23H 1160T-10: specifications and installation checks
This listing refers to BITMAIN model U3S23H, version 1160T-10, a 3U rack-mount SHA-256 miner with Hydro cooling. BITMAIN lists typical values of 1,160 TH/s, 11,020 W at a 35°C coolant inlet and 9.5 J/TH. Actual hashrate can vary by ±3%; wall power and efficiency by ±5%.
Manufacturer specifications
| Algorithm / coins | SHA-256 / BTC, BCH, BSV |
|---|---|
| Typical hashrate | 1,160 TH/s |
| Typical wall power | 11,020 W at 35°C coolant inlet |
| Typical efficiency | 9.5 J/TH |
| Electrical input | Three-phase 380–415 V AC, 50–60 Hz, maximum 24 A; LP34 power port |
| Chassis / net weight | 900 × 482.6 × 130 mm; 42 kg |
| Coolant inlet | 20–50°C |
| Coolant flow / pressure | 16–20 L/min; maximum 3.5 bar |
| Network | RJ45 Ethernet 10/100M |
Plan the electrical supply and liquid loop
The figures above are miner-side requirements, not a complete cooling-system design. Confirm the circuit, connector, rack depth and load with qualified professionals. Match coolant type, pH, flow, pressure, fittings and heat rejection to the BITMAIN U3S23H product manual (v1.0.2). A rack or kit designed for a different chassis format should not be assumed compatible with this 3U model.
Estimate energy separately from revenue
At its typical 11.02 kW draw, one unit uses about 264.48 kWh over 24 hours, before pumps, heat-rejection equipment and other losses. Apply your actual electricity rate and include demand charges, service fees and maintenance. This arithmetic is not a mining-revenue forecast; network difficulty, coin prices, pool fees and uptime also affect results.
Before buying or arranging hosting
- Confirm the exact U3S23H 1160T-10 model and batch.
- Check three-phase supply, rack fit, coolant limits and heat rejection.
- Confirm in writing the price currency, condition, included components, warranty scope, availability and delivery estimate.
- For hosting, confirm capacity, location, electricity billing, cooling, service fees and contract terms in the written offer.
Compare Bitcoin ASIC miners, review Hydro hosting requirements, or request a written quote with your quantity and installation plan.
Source: BITMAIN U3S23H Product Manual, version 1.0.2 (May 2025). Specifications apply to the stated 1160T-10 version; verify the exact unit and batch. Availability, included items, warranty and delivery are confirmed in the written offer.